BHYNT - LPS INSTANT SUPER CLEANER /DEGREASER

  • MSDS: BHYNT
  • Manufacturer: LAPS LABORATORIES INC
  • Product Name: LPS INSTANT SUPER CLEANER /DEGREASER
  • National Stock Number: 6850-01-063-4760
Product Identification

Product ID:LPS INSTANT SUPER CLEANER /DEGREASER
MSDS Date:03/01/1989
FSC:6850
NIIN:01-063-4760
MSDS Number: BHYNT

Responsible Party
LAPS LABORATORIES,INC
4647 HUGH HOWELL ROAD
TUCKER, GA 30084-5096
US

Emergency Phone: 404-934-7800

Info Phone: 404-934-7800

Preparer: JOE TARPLEY

Cage: KO633

Contractor
LPS LABORATORIES, INC.
TUCKER, GA 30085-5052 US

Telephone: 404-934-7800

Cage: 66724

Ingredients

METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 80-100%

OSHA PEL 350 PPM/450 STEL

ACGIH TLV: 350 PPM/450STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 3.0%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93


OTHER COMPONENTS (TYPE NOT SPECIFIED)

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY CAUSE EYE & SKIN
IRRITATION. MAY CAUSE RESPIRATORY TRACT IRRITATION. CENTRAL NERVOUS
SYSTEM DEPRESSANT. LOSS OF CONSCIOUSNESS AND EVEN DEATH CAN OCCUR
AT HIGH LEVELS OF EXPOSURE.LIVER OR KI DNEY DAMAGE POSSIBLE
Effects of Overexposure:INCOORDINATION AND IMPAIRED JUDGMENT MAY OCCUR
AT VAPOR EXPOSURES FROM 500-1000 PPM. DIZZINESS, DROWSINESS, AND
GENERAL ANESTETHIC EFFECTS MAY OCCUR IN RANGES OF 1000 PPM AND
HIGHER.
Medical Cond Aggravated by Exposure:INCREASED SENSITIVITY TO ADRENALIN
MAY BE CAUSED BY OVER EXPOSURE.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE CPR.
IF BREATHING IS DIFFICULT, GIVE OXYGEN. CALL A PHYSICIAN. EYE:
FLUSH IMMEDIATELY WITH LARGE AMOUNTS OF WATER FOR 15 MINUTES. GET
MEDICAL AT TENTION. SKIN: REMOVE CONTAMINATED CLOTHING. WASH WITH
SOAP AND WATER PROMPTLY. INGESTION: DO NOT INDUCE VOMITING. GIVE
MILK OR USP MINERAL OIL. GET IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONE
Lower Limits:7.5
Upper Limits:15.0
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:CONTAINERS MAY BURST. FIRE OR EXCESSIVE
HEAT MAY CAUSE PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.

Accidental Release

Spill Release Procedures:SMALL SPILL: WIPE UP WITH RAGS OR TOWELS.
LARGE SPILLS: WEAR NIOSH APPROVED RESPIRATOR. VENTILATE AREA. DIKE
TO RETAIN FLUID. PUMP UP FREE LIQUID. RESIDUE WILL EVAPORATE
QUICKLY. DO NOT FLUSH TO SEWER OR WATERWAY.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL-VENTILATED
LOCATION, AWAY FROM ANY AREA WHERE THE FIRE HAZARD MAY BE ACUTE.
KEEP CONTAINERS CLOSED WHEN NOT IN USE.
Other Precautions:DO NOT USE WITH ALUMINUM. READ AND FOLLOW DIRECTIONS
ON LABEL. DO NOT REUSE CONTAINERS.

Exposure Controls

Respiratory Protection:IN HIGH VAPOR AREA, USE NIOSH/MSHA APPROVED
RESPIRATOR WITH ORGANIC VAPOR CARTRIDGE. USE SELF-CONTAINED
BREATHING APPARATUS IF VAPOR LEVELS EXCEED 1000 PPM.
Ventilation:LOCAL EXHAUST RECOMMENDED TO CONTROL VAPORS BELOW 50% OF
TLV.
Protective Gloves:NEOPRENE, PVA GLOVES RECOMMENDED.
Eye Protection:USE CHEMICAL SAFETY GOGGLES.
Other Protective Equipment:APRON AND WORK CLOTHING TO MINIMIZE
EXPOSURE. EYE WASH STATION & SAFETY SHOWER RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER USE AND BEFORE EATING,
SMOKING OR USING TOILET FACILITIES. DO NOT BREATH VAPORS OR MIST.
Supplemental Safety and Health
TARGET ORGANS ARE SKIN, CNS, CVS, AND EYES

Chemical Properties

HCC:V2
Boiling Pt:=74.C, 165.2F
Vapor Pres:100
Vapor Density:4.8
Spec Gravity:138
Evaporation Rate & Reference:2.6(ETHYL ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR,COLORLESS LIQUID WITH SWEET ODOR
Percent Volatiles by Volume:100.0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS,STRONG ALKALIES,REACTIVE METALS.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:WHEN INVOLVED IN FIRE,
1,1,1-TRICHLOROETHANE EMITS HIGHLY TOXIC AND IRRITATING HYDROGEN
CHLORIDE AND PHOSGENE FUMES.

Disposal

Waste Disposal Methods:DISOPSE OF I/A/W FEDERAL, STATE & LOCAL
REGULATIONS

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.